A mask-compatible, radiolucent, 8-channel head and neck receive array for MRI-guided radiotherapy treatments and pre-treatment simulation
Zijlema, Stefan Emiel; Breimer, Wico; Gosselink, Mark W J M; Bruijnen, Tom; Arteaga de Castro, Catalina S; Tijssen, Rob H N; Lagendijk, Jan J W; Philippens, Marielle E P; Van den Berg, Cornelis A T
(2022) Physics in medicine and biology, volume 67, issue 13, pp. 1 - 14
(Article)
Abstract
Immobilization masks are used to prevent patient movement during head and neck (H&N) radiotherapy. Motion restriction is beneficial both during treatment, as well as in the pre-treatment simulation phase, where magnetic resonance imaging (MRI) is often used for target definition. However, the shape and size of the immobilization masks hinder
... read more
the use of regular, close-fitting MRI receive arrays. In this work, we developed a mask-compatible 8-channel H&N array that consists of a single-channel baseplate, on which the mask can be secured, and a flexible 7-channel anterior element that follows the shape of the mask. The latter uses high impedance coils to achieve its flexibility and radiolucency. A fully-functional prototype was manufactured, its radiolucency was characterized, and the gain in imaging performance with respect to current clinical setups was quantified. Dosimetry measurements showed an overall dose change of -0.3%. Small, local deviations were up to -2.7% but had no clinically significant impact on a full treatment plan, as gamma pass rates (3%/3 mm) only slightly reduced from 97.9% to 97.6% (clinical acceptance criterion: ≥95%). The proposed H&N array improved the imaging performance with respect to three clinical setups. The H&N array more than doubled (+123%) and tripled (+246%) the signal-to-noise ratio with respect to the clinical MRI-simulation and MR-linac setups, respectively. G-factors were also lower with the proposed H&N array. The improved imaging performance resulted in a clearly visible signal-to-noise ratio improvement of clinically used TSE and DWI acquisitions. In conclusion, the 8-channel H&N array improves the imaging performance of MRI-simulation and MR-linac acquisitions, while dosimetry suggests that no clinically significant dose changes are induced.
show less
Download/Full Text
The full text of this publication is not available.
Keywords: Head, Humans, MR-linac, MRI-guided radiotherapy, MRI-simulation, Magnetic Resonance Imaging, Particle Accelerators, Phantoms, Imaging, Radiotherapy, Image-Guided, Signal-To-Noise Ratio, head and neck, mask-compatible, radiolucent receive array, Radiological and Ultrasound Technology, Radiology Nuclear Medicine and imaging, Research Support, Non-U.S. Gov't, Journal Article
ISSN: 0031-9155
Publisher: IOP Publishing Ltd.
Note: Funding Information: This work is part of the research program HTSM with project number 15354, which is financed by the Netherlands Organization for Scientific Research (NWO) and Philips Healthcare. Publisher Copyright: © 2022 Institute of Physics and Engineering in Medicine.