The Additional Value of Ultrafast DCE-MRI to DWI-MRI and 18F-FDG-PET to Detect Occult Primary Head and Neck Squamous Cell Carcinoma
Martens, Roland M; Stappen, Ruud van der; Koopman, Thomas; Noij, Daniel P; Comans, Emile F; Zwezerijnen, Gerben J; Vergeer, Marije R; Leemans, C René; de Bree, Remco; Boellaard, Ronald; Castelijns, Jonas A; de Graaf, Pim
(2020) Cancers, volume 12, issue 10, pp. 1 - 15
(Article)
Abstract
To evaluate diagnostic accuracy of qualitative analysis and interobserver agreement of single ultrafast-DCE, DWI or 18F-FDG-PET and the combination of modalities for the detection of unknown primary tumor (UPT) in patients presenting with cervical lymph node metastasis from squamous cell carcinoma (SCC). Between 2014-2019, patients with histologically proven cervical lymph
... read more
node metastasis of UPT SCC were prospectively included and underwent DWI, ultrafast-DCE, and 18F-FDG-PET/CT. Qualitative assessment was performed by two observers per modality. Interobserver agreement was calculated using the proportion specific agreement. Diagnostic accuracy of combined use of DWI, ultrafast-DCE and 18F-FDG-PET/CT was assessed. Twenty-nine patients were included (20 males. [68%], median age 60 years). Nine (31%) primary tumors remained occult. Ultrafast-DCE added reader confidence for suspicious locations (one additional true positive (5%), 2 decisive true malignant (10%). The per-location analysis showed highest specific positive agreement for ultrafast-DCE (77.6%). The per-location rating showed highest sensitivity (95%, 95%CI = 75.1-99.9, YI = 0.814) when either one of all modalities was scored positive, and 97.4% (95%CI = 93.5-99.3, YI = 0.774) specificity when co-detected on all. The per-patient analysis showed highest sensitivity (100%) for 18F-FDG-PET/CT (YI = 0.222) and either DWI or PET (YI = 0.111). Despite highest trends, no significant differences were found. The per-patient analysis showed highest specific positive agreement when co-detected on all modalities (55.6%, 95%CI = 21.2-86.3, YI = 0.456). Ultrafast-DCE showed potential to improve detection of unknown primary tumors in addition to DWI and 18F-FDG-PET/CT in patients with cervical squamous cell carcinoma lymph node metastasis. The combined use of ultrafast-DCE, DWI and 18F-FDG-PET/CT yielded highest sensitivity.
show less
Download/Full Text
Keywords: DWI, Head and neck neoplasms, MRI, PET, Ultrafast DCE, Unknown primary, head and neck neoplasms, ultrafast DCE, unknown primary, Oncology, Cancer Research, Journal Article
ISSN: 2072-6694
Publisher: Multidisciplinary Digital Publishing Institute (MDPI)
Note: Funding Information: Funding: This research was funded by the Netherlands Organization for Health Research and Development, grant 10-10400-98-14002. The funding source had no involvement in collection, analysis, data interpretation, writing of the report, nor in the decision to submit the article for publication. Publisher Copyright: © 2020 by the authors. Licensee MDPI, Basel, Switzerland. Copyright: Copyright 2020 Elsevier B.V., All rights reserved.
(Peer reviewed)