Abstract
In this paper a methodology is described combining 2D height maps with 3D building simulations and PV performance software to assess the solar potential at Utrecht Science Campus. Results show that adding facades and parking lots doubles the roof potential, with levelized cost of energy values of 0.068 - 0.092