Prolonged Electromechanical Interval Unmasks Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy in the Subclinical Stage
Mast, Thomas P; Teske, Arco J; Te Riele, Anneline Sjm; Groeneweg, Judith A; Van Der Heijden, Jeroen F; Velthuis, Birgitta K; Loh, Peter; Doevendans, Pieter A; Van Veen, Toon A; Dooijes, Dennis; De Bakker, Jacques M; Hauer, Richard N; Cramer, Maarten J
(2016) Journal of Cardiovascular Electrophysiology, volume 27, issue 3, pp. 303 - 314
(Article)
Abstract
INTRODUCTION: Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is characterized by high incidence of ventricular arrhythmias. Overt ARVD/C is preceded by a subclinical stage with lack of detectable ECG and structural abnormalities. Activation delay is present before structural abnormalities and is a hallmark of arrhythmogenesis. Deformation imaging may unmask activation delay in
... read more
the subclinical stage. METHODS: Three groups were compared: (1) mutation-positive definite ARVD/C-patients fulfilling 2010 Task Force criteria (TFC) (n = 44); (2) asymptomatic mutation carriers not fulfilling TFC and without history of ventricular arrhythmias (n = 31); and (3) controls (n = 30). All underwent ECG and echocardiographic deformation imaging. As a surrogate for local activation delay the electromechanical interval (EMI) was measured, defined as time between onset-QRS and onset of shortening. Arrhythmic outcome (PVC-count, VT) of asymptomatic mutation carriers was correlated with EMI and ECG TFC. RESULTS: In definite ARVD/C-patients, EMI was prolonged in all lateral RV segments. In asymptomatic mutation carriers, prolonged EMI was detected in the subtricuspid area in 14/31. Terminal activation duration ≥55 milliseconds (definition: supporting information) was the only ECG abnormality in this group (8/31). After a mean follow-up of 4.2 ± 3.1 years 10/31 asymptomatic mutation carriers experienced arrhythmic outcome. Prolonged subtricuspid EMI was the only parameter significantly associated with arrhythmogenesis during follow-up. CONCLUSION: In ARVD/C-patients, EMI prolongation was present throughout the RV. In asymptomatic mutation carriers, prolonged EMI in the subtricuspid area is often detected without any additional abnormalities. These preliminary results indicate that prolonged EMI is a new parameter unmasking activation delay in the subclinical stage and may contribute to risk stratification.
show less
Download/Full Text
The full text of this publication is not available.
Keywords: activation delay, arrhythmogenic right ventricular dysplasia/cardiomyopathy, echocardiography, diagnosis, deformation imaging, risk stratification, ventricular arrhythmias, Journal Article, Research Support, Non-U.S. Gov't
ISSN: 1045-3873
Publisher: Wiley-Blackwell
Note: © 2015 Wiley Periodicals, Inc.
(Peer reviewed)