Safety of a Scout Dose Preceding Hepatic Radioembolization with 166Ho Microspheres
Prince, Jip F; van Rooij, Rob; Bol, Gijsbert H; de Jong, Hugo W A M; van den Bosch, Maurice A A J; Lam, Marnix G E H
(2015) Journal of Nuclear Medicine, volume 56, issue 6, pp. 817 - 23
(Article)
Abstract
UNLABELLED: Before (166)Ho radioembolization, a small batch of the same type of microspheres is administered as a scout dose instead of the conventional (99m)Tc-macroaggregated albumin ((99m)Tc-MAA). The (166)Ho scout dose provides a more accurate and precise lung shunt assessment. However, in contrast to (99m)Tc-MAA, an unintended extrahepatic deposition of this
... read more
β-emitting scout dose could inflict radiation damage, the extent of which we aimed to quantify in this study. METHODS: All patients eligible for radioembolization in our institute between January 2011 and March 2014 were reviewed. Of the extrahepatic depositions of (99m)Tc-MAA on SPECT, the amount and volume were measured. These were used to calculate the theoretic absorbed dose in the case a (166)Ho scout dose had been used. The extrahepatic activity was measured as the sum of all voxels of the deposition. Volumes were measured using a threshold technique including all voxels from the maximum voxel intensity up to a certain percentage. The threshold needed to obtain the true volume was studied in a phantom study. RESULTS: In the phantom study, a threshold of 40% was found to overestimate the volume, with the consequence of underestimating the absorbed dose. Of 160 patients, 32 patients (34 cases) of extrahepatic deposition were identified. The depositions contained a median of 1.3% (range, 0.1%-19.5%) of the administered activity in a median volume of 6.8 mL (range, 1.1-42 mL). The use of a scout dose of 250 MBq of (166)Ho microspheres in these cases would theoretically have resulted in a median absorbed dose of 6.0 Gy (range, 0.9-374 Gy). The dose exceeded a limit of 49 Gy (reported in 2013) in 2 of 34 cases (5.9%; 95% confidence interval, 0.7%-20.1%) or 2 of 160 (1.3%; 95% confidence interval, 0.1%-4.7%) of all patients. In these 2 patients with a large absorbed dose (112 and 374 Gy), the culprit vessel was identified in 1 case. CONCLUSION: Extrahepatic deposition of a (166)Ho scout dose seems to be theoretically safe in most patients. Its safety in clinical practice is being evaluated in ongoing clinical trials.
show less
Download/Full Text
The full text of this publication is not available.
Keywords: Adult, Aged, Aged, 80 and over, Biological Markers, Carcinoma, Hepatocellular, Cross-Sectional Studies, Embolization, Therapeutic, Female, Holmium, Humans, Liver, Liver Neoplasms, Lung, Male, Microspheres, Middle Aged, Phantoms, Imaging, Radioisotopes, Retrospective Studies, Technetium Tc 99m Aggregated Albumin, Tomography, Emission-Computed, Single-Photon, Yttrium Radioisotopes, Journal Article
ISSN: 0161-5505
Publisher: Society of Nuclear Medicine Inc.
Note: © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
(Peer reviewed)